16 zones fire alarm panel AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision.
AW-FTP2016 (16 zones) fire telephone panel is a new fire special communications equipment, when the fire accident, which provides a convenient means of communication, the fire control and alarm systems necessary communications products. Wall-mounted structure is easy to install, suitable for small systems.
1by1m fire blanket is suitable for fires involving cooking fats and oils up to 3 litres and comes with a 5-year warranty. Larger fire blankets are available for commercial use.
The 1.1m x 1.1m fire blanket is suitable for small kitchen areas, caravan parks, holiday homes, and landlord flats.
The AW-CFP2166 series 2 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
4Kg Dry powder Fire Extinguisher
ABC Extinguisher
Ideal for a small office set up
4zones fire alarm panel Asenware Conventional Fire Panel, AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of the conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision.
ITEM | 8zones fire alarm panel |
Model No. | AW-CFP2166-04-16 |
Mains supply voltage | 110VAC or 240VAC |
Internal power supply | 27.2VDC |
Total output current limited | 3A @ 240VAC |
Batteries (Default Configuration) | 12V2AH*2-24VDC in Total |
End of Line device | 6.8k Q,5% tolerance, 0.25W (color code-blue, grey, red, gold) |
End of line resistor value | 6.8k 22,5% tolerance, 0.25W (color code-blue, grey, red, gold) |
Dimensions(mm) | 395*502″124mm |
Weight (without batteries) | 7kg |
Weight (with batteries) | 9.6kg |
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
- Equipment operation stable & reliable
- Easy to install & wire
- Equipment has also issued two kinds of sound and flash an alarm signal, even people with disabilities can be a timely response to evacuate.
AVAILABILITY: In stock
fire alarm cable is available at www.affrosonicsystems.com
- 100 meters roll
- 1.5mm
AVAILABILITY: In stock
Operating Voltage | 2* AA or 3VDC battery |
Operating current | monitoring status≤10uA, alarm status≤20mA |
Maximum Alarm Current (LED on): | ≤100mA@3VDC |
Operating Humidity Range: | ≤95%RH(40°C±2°C) |
Operating Temperature Range: | -10°C to 50°C (14°F to 122°F) |
Smoke Alarm Sensitivity: | 0.18-0.26dBM |
Alarm level: | ≥85db /3m |
A Delivery hosehelps to provide water under pressure. The pressure enables the water that is projected out of the nozzle, at the end of the hose, to reach the fire.
- Operating voltage: 9VDC(with battery 6F22)
- Operating current: monitoring status≤8uA, alarm status≤20mA
- Operating temperature: -10℃~55℃,Relative humidity: ≤95%(non-condensing)
- Protection class: IP20
- Application: For indoor use only
- Smoke Alarm Sensitivity: 0.18 to 0.26 dBM
- Alarm Level: ≥85dB@3m and ≥93dB@1m
- Materials and colors: ABS, white
- Size: 105mm*105mm*43mm
- Weight: about 130g